diff options
Diffstat (limited to 'host/docs')
| -rw-r--r-- | host/docs/usrp_x3x0_config.rst | 7 | 
1 files changed, 4 insertions, 3 deletions
| diff --git a/host/docs/usrp_x3x0_config.rst b/host/docs/usrp_x3x0_config.rst index 9cb000275..22ef8c595 100644 --- a/host/docs/usrp_x3x0_config.rst +++ b/host/docs/usrp_x3x0_config.rst @@ -69,19 +69,20 @@ Configuring the MTU  -------------------------------------  In order to achieve maximum performance, we recommend setting the MTU size to  9000 for 10 GigE and 1500 for 1 GigE. It is possible to use smaller MTUs, but this -can affect performance. With some NICs, setting the MTU too high can also cause issues, -though. To set the MTU to 9000, you can use the following command: +can affect performance. With some NICs, setting the MTU too high can also cause issues. +To set the MTU to 9000, you can use the following command:  ::      sudo ifconfig <interface> mtu 9000 # For 10 GigE +    sudo ifconfig <interface> mtu 1500 # For 1 GigE  Using these MTUs will set the frame sizes for UHD communication to 8000 and 1472,  respectively.  In some cases, specifying the frame size manually by adding the argument  "<send/recv>_frame_size=1472" can solve issues. Note that a frame size of 1472 will limit -the available sampling rate, although this is likely not a problem issue on 1 GigE. +the available sampling rate, although this is not a problem on 1 GigE.  Configuring the Firewall | 
